Author: Frei, F.
Paper Title Page
WEPP026 Electron Bunch Compression Monitors for Short Bunches - Commissioning Results from SwissFEL 578
 
  • F. Frei, R. Ischebeck
    PSI, Villigen PSI, Switzerland
 
  In SwissFEL, by using three magnetic chicanes, 3ps long electron bunches can by compressed by a factor of more than 100 down to a few fs in order to generate ultra short X-ray pulses. In order to meet the envisaged beam performance, noninvasive longitudinal diagnostic after each compression stage is essential. These bunch compression monitors measure relative bunch length changes on a shot-to-shot basis by detecting coherent edge, synchrotron or diffraction radiation emitted by the electron bunches. While after the first two magnetic chicanes, a wide spectral part is integrated on a single broadband detector, an infrared spectrometer installed after the third magnetic chicane is providing more detailed information. Here, we will mainly report on commissioning results of the third bunch compression monitor for electron bunches of a few fs.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2019-WEPP026  
About • paper received ※ 03 September 2019       paper accepted ※ 10 September 2019       issue date ※ 10 November 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)