Paper |
Title |
Page |
MOPP022 |
Neutron Sensitive Beam Loss Monitoring System for the ESS Linac |
131 |
|
- I. Dolenc Kittelmann, F.S. Alves, E.C. Bergman, C.S. Derrez, V. Grishin, K.E. Rosengren, T.J. Shea
ESS, Lund, Sweden
- Q. Bertrand, T.J. Joannem, Ph. Legou, Y. Mariette, V. Nadot, T. Papaevangelou, L. Segui
CEA-IRFU, Gif-sur-Yvette, France
- W. Cichalewski, G.W. Jabłoński, W. Jałmużna, R. Kiełbik
TUL-DMCS, Łódź, Poland
|
|
|
The European Spallation Source, currently under construction in Lund, Sweden, will be a neutron source based on partly superconducting linac, accelerating protons to 2GeV with a peak current of 62.5mA, ultimately delivering a 5MW beam to a rotating tungsten target. For a successful tuning and operation of a linac, a Beam Loss Monitoring (BLM) system is required. The system is designed to protect the machine from beam-induced damage and unnecessary activation of the components. This contribution focuses on one of the BLM systems to be deployed at the ESS linac, namely the neutron sensitive BLM (nBLM). Recently, test of the nBLM data acquisition chain including the detector has been performed at LINAC4, at CERN. The test represents first evaluation of the system prototype in realistic environment. Results of the test will be presented together with an overview of the ESS nBLM system.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IBIC2019-MOPP022
|
|
About • |
paper received ※ 04 September 2019 paper accepted ※ 07 September 2019 issue date ※ 10 November 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
MOPP023 |
Ionisation Chamber Based Beam Loss Monitoring System for the ESS Linac |
136 |
|
- I. Dolenc Kittelmann, F.S. Alves, E.C. Bergman, C.S. Derrez, T.J. Grandsaert, V. Grishin, T.J. Shea
ESS, Lund, Sweden
- W. Cichalewski, G.W. Jabłoński, W. Jałmużna, R. Kiełbik
TUL-DMCS, Łódź, Poland
|
|
|
The European Spallation Source, currently under construction in Lund, Sweden, will be a neutron source based on partly superconducting linac, accelerating protons to 2GeV with a peak current of 62.5mA, ultimately delivering a 5MW beam to a rotating tungsten target. One of the most critical elements for the protection of an accelerator is its Beam Loss Monitoring (BLM) system. The system is designed to protect the machine from beam-induced damage and unnecessary activation of the components. This contribution focuses on one of the BLM systems to be deployed at the ESS linac, namely the Ionisation Chamber based BLM (ICBLM). Several test campaigns have been performed at various facilities. Results of these tests will be presented here together with an overview of the ESS ICBLM system.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IBIC2019-MOPP023
|
|
About • |
paper received ※ 04 September 2019 paper accepted ※ 07 September 2019 issue date ※ 10 November 2019 |
|