JACoW logo

Joint Accelerator Conferences Website

The Joint Accelerator Conferences Website (JACoW) is an international collaboration that publishes the proceedings of accelerator conferences held around the world.


RIS citation export for MOPP036: SPIRAL2 Diagnostic Qualifications with RFQ beams

TY  - CONF
AU  - Jamet, C.
AU  - Andre, T.
AU  - Langlois, V.
AU  - Le Ster, T.
AU  - Ledu, G.
AU  - Legallois, P.
AU  - Leloir, S.
AU  - Lepoittevin, F.
AU  - Loret, S.
AU  - Potier de courcy, C.
AU  - Revenko, R.V.
ED  - Schaa, Volker RW
ED  - Jansson, Andreas
ED  - Shea, Thomas
ED  - Olander, Johan
TI  - SPIRAL2 Diagnostic Qualifications with RFQ beams
J2  - Proc. of IBIC2019, Malmö, Sweden, 08-12 September 2019
CY  - Malmö, Sweden
T2  - International Beam Instrumentation Conferenc
T3  - 8
LA  - english
AB  - The SPIRAL2 accelerator, built on the GANIL’s facility, at CAEN in FRANCE is dedicated to accelerate light and heavy ion beams up to 5mA and 40 MeV. The continuous wave accelerator is based on two ECR ion sources, a RFQ and a superconducting LINAC. The beam commissioning of the RFQ finished at the end of 2018. This paper presents the Diagnostic-Plate installed behind the RFQ, with all associated accelerator diagnostics. Diagnostic monitors, measured beam parameters, results are described and analyzed. A brief presentation of the next steps is given.
PB  - JACoW Publishing
CP  - Geneva, Switzerland
SP  - 188
EP  - 192
KW  - rfq
KW  - linac
KW  - emittance
KW  - diagnostics
KW  - MEBT
DA  - 2019/11
PY  - 2019
SN  - 2673-5350
SN  - 978-3-95450-204-2
DO  - doi:10.18429/JACoW-IBIC2019-MOPP036
UR  - http://jacow.org/ibic2019/papers/mopp036.pdf
ER  -