MOPB09 | Comparison Among Different Tune Measurement Schemes at HLS-II Storage Ring | 93 |
|
||
Tune measurement is one of the most significant beam diagnostics at HLS-II storage ring. When measuring tune, higher tune spectral component and lower other compo-nents are expected, so that the tune measurement will be more accurate. To this end, a set of BBQ (Base Band Tune) front-end based on 3D (Direct Diode Detection) technique has previously developed to improve the effec-tive signal content and suppress other components. Em-ploying the BBQ front-end, four different tune measure-ment schemes are designed and related experiments per-formed on the HLS-II storage ring. Experimental results and analysis will be presented later. | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2018-MOPB09 | |
About • | paper received ※ 05 September 2018 paper accepted ※ 11 September 2018 issue date ※ 29 January 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
TUPC12 | Beam Transverse Quadrupole Oscillation Measurement in the Injection Stage for the HLS-II Storage Ring | 325 |
|
||
Funding: Supported by the National Science Foundation of China (Grant No. 11705203, 11575181, 11605202) and the National Key Research and Development Program of China(No. 2016YFA0402000) Beam transverse quadrupole oscillation can be excited in the injection stage if injected beam parameters(twiss parameters or dispersion) are not matched with the parameters in the injection point of the storage ring. In order to measure the beam transverse quadrupole oscillation in the injection stage for the HLS-II storage ring, some axially symmetric stripline BPMs were designed. Transverse quadrupole component for these BPMs was simulated and off-line calibrated. Beam transverse quadrupole oscillation has been measured when beam was injected into the HLS-II electron storage ring. The spectrum of the transverse quadrupole component showed that beam transverse quadrupole oscillation is very obvious in the injection stage and this oscillation isn’t the second harmonic of beam betatron oscillation. The relationship between transverse quadrupole oscillation and beam current was also analyzed and the result shows that the relationship is not linear. |
||
![]() |
Poster TUPC12 [0.467 MB] | |
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2018-TUPC12 | |
About • | paper received ※ 06 September 2018 paper accepted ※ 12 September 2018 issue date ※ 29 January 2019 | |