  The Facility of Rare Isotope Beams (FRIB) superconducting magnets are used to focus and steer the heavy ion beams of the FRIB driver linac. All the magnets are designed as a solenoid with bucking coils to suppress the stray field and have superconducting dipole correctors to steer both horizontal and vertical field. Two types of magnets are manufactured in China and some of them have been tested at Institute of Modern Physic(IMP). This paper describes the measurement facilities and magnetic axis measurement method. We also present a summary of the measurement process and test results of the magnetic performance for the magnets.  
poster icon Poster MOPB02 [0.892 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-HIAT2018-MOPB02  
About • paper received ※ 09 November 2018       paper accepted ※ 16 January 2019       issue date ※ 05 November 2019  