Measurement Facility and Test Results for FRIB Superconducting Magnets at IMP |
33 |
|
- W.J. Yang
University of Chinese Academy of Sciences, Beijing, People’s Republic of China
- L.Z. Ma, E.M. Mei, D.S. Ni, B.M. Wu, W. Wu, W.J. Yang
IMP/CAS, Lanzhou, People’s Republic of China
|
|
|
The Facility of Rare Isotope Beams (FRIB) superconducting magnets are used to focus and steer the heavy ion beams of the FRIB driver linac. All the magnets are designed as a solenoid with bucking coils to suppress the stray field and have superconducting dipole correctors to steer both horizontal and vertical field. Two types of magnets are manufactured in China and some of them have been tested at Institute of Modern Physic(IMP). This paper describes the measurement facilities and magnetic axis measurement method. We also present a summary of the measurement process and test results of the magnetic performance for the magnets.
|
|
|