Paper |
Title |
Page |
TUP009 |
Cyclotron Cavity Pollution Recovery |
169 |
|
- J. Dabin, B. Adant, P. Cailliau, K. Ellis, E. Forton, J. Mandrillon, T.S. Ponter, P. Verbruggen
IBA, Louvain-la-Neuve, Belgium
|
|
|
In a cyclotron, RF cavities are usually among the most reliable subsystems, provided minimal care and maintenance. Nevertheless, several parameters may affect cavity performance after several years of operation. To name a few typical causes of degradation are: decreasing vacuum quality, various gas loads or gas qualities triggering adverse effects, deposition of highly emissive material on the cavity due to overheating of components like pass-through connectors, accidental use of chemicals or not-suitable greases. The cavity status can be monitored but, in the worst cases, the RF tuning may become difficult and it is important to apply methods in order to recover a better cavity Q-factor. In this paper, cases of cavity pollution will be shown, their potential root causes discussed and some recovery methods described.
|
|
|
Poster TUP009 [0.398 MB]
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-Cyclotrons2019-TUP009
|
|
About • |
paper received ※ 12 September 2019 paper accepted ※ 25 September 2019 issue date ※ 20 June 2020 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THD02 |
Central Region Upgrade for the Jyväskylä K130 Cyclotron |
326 |
|
- T. Kalvas, P.M.T. Heikkinen, H.A. Koivisto
JYFL, Jyväskylä, Finland
- E. Forton, W.J.G.M. Kleeven, J. Mandrillon, V. Nuttens
IBA, Louvain-la-Neuve, Belgium
|
|
|
The Jyväskylä K130 cyclotron has been in operation for more than 25 years providing beams from H to Au with energies ranging from 1 to 80 MeV/u for nuclear physics research and applications. At the typical energies around 5 MeV/u used for the nuclear physics program the injection voltage used is about 10 kV. The low voltage limits the beam intensity especially from the 18 GHz ECRIS HIISI. To increase the beam intensities the central region of the K130 cyclotron is being upgraded by increasing the injection voltage by a factor of 2. The new central region with spiral inflectors for harmonics 1-3 has been designed. The new central region shows better transmission in simulations than the original one for all harmonics and especially for h=2 typically used for nuclear physics. The engineering design for the new central region is being done.
|
|
|
Slides THD02 [12.967 MB]
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-Cyclotrons2019-THD02
|
|
About • |
paper received ※ 15 September 2019 paper accepted ※ 27 September 2019 issue date ※ 20 June 2020 |
|